Room radiator sizing

Estimate the steady-state heat loss of one room. Whose figures these are, and how it is calculated.

What this estimates

A room’s heat loss. It does not tell you which radiator to buy, and it does not judge whether a radiator is adequate.

The figures

In Simple mode the tool applies a YLE design assumption for each surface. Those are our own figures — not industry-standard, not typical, not recognised values. Every one is shown in the working.

The property

The property

Asked once — every room in this property shares these.

The property — asked once

Property type
Recorded only. It never affects the result.
Where in the country
Needed to continue. Sets the outside design temperature. This one does change the result.

The room

Measure it, say where it sits, and say how warm you're designing it to be.

The property

postcode · type · region · house temperature — set once

Measured inside the room — wall face to wall face, floor to ceiling.

A bay, dormer or sloping ceiling is not modelled, so this room's result will be low. Do not enter the feature as a separate room — that would count its ventilation twice. Calculate the additional external wall, roof and glazing loss separately and add it to this result.

How warm this room is kept

Not set yet

the same as the rest of the house

Only this room. Everything else keeps the house figure.
Existing radiators

Recorded only. Nothing is calculated from these, and the result does not change.

How many in this room
Where is it in the building?
This decides whether the floor and the ceiling lose anything. Their areas are the room's own — never asked.
Draughtiness
Starts at Typical. Change it if the room is visibly draughty or has a flue, chimney or permanent vent.

Which walls face outside?

Tap them. Everything else is treated as a warm room next door, which loses nothing.

Enter the room's length and width and its plan appears here.

Windows and doors

Only the ones in an outside wall. They come out of the wall area.

Windows

How many

Each window is measured on its own — nothing is pre-filled and nothing carries over from another window or another room. Double is treated as uncoated — the figure errs high on modern units.

Outside doors

How many
Measured on its own — nothing pre-filled.

Room 1

No result yet

Something above is still needed.

Through the fabric
Ventilation

Based on YLE design assumptions for the constructions you chose, not on measured values for this building.

How this was calculated

Every assumption used, and every surface

SurfaceConstructionUSourceNet m²Beyond °CΔTLoss W

Ventilation: × air changes × m³ × K = W

BTU/h conversion: displayed watts × 3.412142, rounded to the nearest BTU/h.

Every figure above is a YLE design assumption for the construction you chose — not a measured value for this building, and not an industry-standard or recognised figure.

Every room in this property

The property

Postcode

Property type

Where in the country

How warm you keep the house

  • Room 1

    not measured

Don’t add these figures together to size a boiler or heat pump.

Something look wrong in this calculator? Tell us — it is the most useful message you can send.